With over 30 years of research, we have mastered the manufacturing of WRe products. Our WRe3/WRe25 thermocouples now reach 0.25%t and have successfully substituted Pt-Rh thermocouple used for measuring temperature of liquid steel in China.
Specifications:
Grade Diameter(mm) Working Temperature Accuracy Uniformity (at 1500 ºC,µv)
WRe3 WRe25
I 0.1 ≤ 1800 ºC 0.25%t ≤ 35 ≤ 25
II 0.1,0.25,0.5 ≤ 2000 ºC ±0.5%t ≤ 45 ≤ 35
Application: Used for hot extrusion of copper and its alloys, including Ti, stainless steel and Al alloys
![]() |
|||||||||||
ECOTUNGSTEN™ Manufacturing Services 2535 Muirfield Way, Gilroy, CA 95020, USA • 408-838-5158 • 760-284-9025 fax • sales.usa@ecotungsten.com Copyright© ECOTUNGSTEN 2007 — All Rights Reserved |
|||||||||||